- Contact Person : Mr. chen misen
- Company Name : Shenzhen Soro Electronics Co., Ltd.
- Tel : 86-0755-81495853
- Fax : 86-0755-81495855
- Address : Guangdong,shenzhen,Guangyang Industrial Park ,Hi-tech Development Zone ,Fuyong Town, Baoan District
- Country/Region : China
- Zip : 518103
Large Power UPS GP9335C 120-800KVA (Efficiency of Machine >94% and reach 98% in ECO Mode )
Large Power 0.9 Output Power Factor UPS GP9335C 120-800KVA ( Low Frequency Online UPS) :
1) Rated at 0.9 output power factor, more applicable to server computer and network
center that use PFC technology in a large scale, and deliver more Active power than
conventional UPS
2) Advanced distributed active parallel technology can realize parallel operation of 6 UPS
units without the need of centralized bypass cabinet
3) 6-inch extra large LCD that display 12 language( Chinese .English.Russian.Spanish.French…)
4) The efficiency of the machine is more than 94%, and reach 98% in ECO mode.
5) Use advanced 6th generation DSP and full digital control technologies to realize higher
system stability
6) Intelligent battery management maintains battery automatically to prolong the
battery life
7) Standard input/output filter improves the system EMC performance
Low Frequency Online UPS GP9335C Series Construction:
GP9335C Series Technical Specifications:
Model | GP9335C | ||||||||||
Rectifier Type | 6p | 12p | 6p | 12p | 6p | 12p | 6p | 12p | 6p | 12p | |
Rated Nominal | 120KVA/108KW | 160KVA/144KVA | 200KVA/180KW | 300KVA/270KW | 400KVA/360KW | ||||||
Rated input voltage | 380/400/415VAC 3-phase 4-wire | ||||||||||
Rated frequency | 50/60HZ | ||||||||||
Input parameters | |||||||||||
Input voltage range | ±25% | ||||||||||
Input frequency range | 45Hz~65Hz | ||||||||||
Input soft start function | 0-100% 5-300settable | ||||||||||
Input power factor | >0.98(If harmonic filter is added) | ||||||||||
Input harmonic current (THDi) | ‹4.5%(If harmonic filter is added) | ||||||||||
Bypass | |||||||||||
Bypass voltage range | -20%~+15% | ||||||||||
Bypass frequency range | 50/60HZ±10% | ||||||||||
Output parameters | |||||||||||
Inverter output voltage | 380/400/415VAC 3-phase 4-wire | ||||||||||
Voltage stability | ±1%(Steady status),±3%(Transient status) | ||||||||||
Frequency | 50/60Hz | ||||||||||
Mains power synchronization window | ±5% | ||||||||||
Actually measured frequency accuracy (internal clock) | 50/60Hz±0.01Hz | ||||||||||
Output power factor | 0.9(Output 90kW per 100kVA) | ||||||||||
Transient response time | <5ms | ||||||||||
Inverter overload capability | At 0.9 power factor, 110% for 1 hour, 125% for 10 minutes and 150% for 60s | ||||||||||
Short circuit current from inverter | 3ph 1.5ln for 5seconds,1ph 2.9ln for 5seconds | ||||||||||
Maximum Bypass capability | 1000% for 100ms | ||||||||||
Phase shift characteristic | With 100% balanced load | <1° | |||||||||
With 100% imbalance load | <1° | ||||||||||
Total harmonic Distortion(THDv) | 100% linear load | <1% | |||||||||
100% non-linear load | <3% | ||||||||||
System efficiency (full load) | Up to 94% (inverter efficiency is up to 98%) | ||||||||||
Rectifier output parameters | |||||||||||
Charger output voltage stability | 1% | ||||||||||
DC ripple voltage | ≤1% | ||||||||||
Operating environment | |||||||||||
Operating temperature range | 0~40°C | ||||||||||
Storage temperature | -25~70°C(Without battery) | ||||||||||
Relative humidity | 0~95% No condensation | ||||||||||
Noise (1m) | 58-68dB | ||||||||||
Protection level | IP20 | ||||||||||
Standard | Safety: IEC60950-1 IEC62040-1-1 UL1778 EMC IEC62040-2 CLASS C2 EN50091-2 CLASS A Design and Test IEC62040-3 |
Large Power UPS GP9335C 120-800KVA (Efficiency of Machine >94% and reach 98% in ECO Mode )